Ortal – Front Facing Gas Fire
Ortal

Ortal Front Facing Gas Fire

Clear fronted Ortal fires can be square, portrait or landscape in aspect. Standard widths range from an easy-to-accommodate 40cm to a spectacular 400cm. Heights vary from 38cm to a lofty 90cm.           

          

Ortal Clear Front 40

Ortal Clear Front 60 x 80

Ortal Clear Front 75 x 65

Ortal Clear Front 75

Ortal Clear Front 110

Ortal Clear Front 130

Ortal Clear Front 150

Ortal Clear Front 170

Ortal Clear Front 200

Ortal Clear Front 250

Ortal Minimal 110

Ortal Minimal 130

          

Standard features:

  • Clear ceramic glass for an unimpaired visual effect.
  • Frameless design for a fuller view of the fire
  • Remote handset- this controls ignition and also incorporates timer and thermostat.
  • Battery powered control box – continues to operate during a power cut.
  • Decorative fuel bed - a choice of large or small logs, large or small pebbles, driftwood, glass beads.
  • Balanced flue - A balanced flue gas fire is room-sealed with a glass front. The flue uses natural draught to draw fresh air in and discharge the gas exhaust to outside.

Optional features:

  • Dual line burner- for individual control of each line of flame (not available on 40 models)
  • Reflecting Interior - to add extra depth to the flame effect.
  • Interior lights.
  • Natural Gas or LPG
  • Mains electrical connection for the control box - no changing of batteries required.
  • Fan exhaust system- allows longer flue runs up to 20-30 metres and up to 6 bends

Special options (must be specified at time order)

  • Protective mesh screen- for ultimate safety in the home or public areas. Can be easily removed or replaced according to circumstances.
  • Double Glazing - to keep the outer glass surface cooler, perfect for public areas

           

        

Choose from these alternative fuel bed effects, which are included in the price of the fire.

                                                                 

                        

                        

  

Certain items are shown for display purposes only - please ask for details.

For further information on any of our products, or to place an order, please contact us. Telephone: 01773 820940 Fax: 01773 599309 E-mail: info@robeys.co.uk ( or click on Make an Enquiry)

  

  • TECHNICAL DATA/DIMENSIONS

    Clear 40 Front

    • Balanced Flue using 100/150 mm
    • One phase burner
    • Heat input (KW) NG\LPG: 7 \ 5.2
    • Heat output (KW) NG\ LPG: 6 \ 4.3
    • Optional –
    • Fan exhaust system
    • Heat Barrier available with Double glazed glass or net

      Download the CAD Drawing (DWG).

      

    Clear 40 High 70

    • Balanced Flue using 100/150 mm
    • One phase burner
    • Heat input (KW) NG\LPG: 7 \ 5.2
    • Heat output (KW) NG\ LPG: 6 \ 4.3
    • Optional –
    • Fan exhaust system
    • Heat Barrier available with Double glazed glass or net

      

    Download the CAD Drawing (DWG).

            

    Clear 40 High 90

    • Balanced Flue using 100/150 mm
    • One phase burner
    • Heat input (KW) NG\LPG: 7 \ 5.2
    • Heat output (KW) NG\ LPG: 6 \ 4.3
    • Optional –
    • Fan exhaust system
    • Heat Barrier available with Double glazed glass or net

      

    Download the CAD Drawing (DWG).

         

    Clear Front 60 x 80

    • Balanced Flue using 100/150 mm
    • One phase burner
    • Heat input (KW) NG\LPG: 7 \ 5.2
    • Heat output (KW) NG\ LPG: 6 \ 4.3
    • Two phase burner
    • Heat input (KW) NG\LPG: 8.12 \ 6.99
    • Heat output (KW) NG\ LPG: 6.77 \ 5.37
    • Optional –
    • Fan exhaust system
    • Heat Barrier available with Double glazed glass or net

     Download the CAD Drawing (DWG).

         

    Clear Front 75 x 65

    • Balanced Flue using 100/150 mm
    • One phase burner
    • Heat input (KW) NG\LPG: 7 \ 5.2
    • Heat output (KW) NG\ LPG: 6 \ 4.3
    • Two phase burner
    • Heat input (KW) NG\LPG: 9.52 \ 6.99
    • Heat output (KW) NG\ LPG: 4.3 \ 5.37
    • Optional –
    • Fan exhaust system
    • Heat Barrier available with Double glazed glass or net

    Download the CAD Drawing (DWG). 

    Clear Front 75

    • Heat Output, Natural Gas, Single Line:- 6kW ( Heat Input 7kW )
    • Heat Output, Natural Gas, Dual Line:- 6.77kW ( Heat Input 8.12kW )
    • Efficiency Natural Gas:- 85.7%
    • Heat Output, LPG, Single Line:- 4.3kW ( Heat Input 5.2kW )
    • Heat Output, LPG, Dual Line:- 5.37kW ( Heat Input 6.99kW
    • Efficiency LPG:- 82.7%

    Clear Front 110

    • Heat Output, Natural Gas, Single Line:- 6.8kW ( Heat Input 8.9kW )
    • Heat Output, Natural Gas, Dual Line:- 7.27kW ( Heat Input 9.52kW )
    • Efficiency Natural Gas:- 75.9%
    • Heat Output, LPG, Single Line:- 5.2kW ( Heat Input 7.5kW )
    • Heat Output, LPG, Dual Line:- 6.5kW ( Heat Input 9.37kW
    • Efficiency LPG:- 72.1%

    Clear Front 110 High

    • Heat Output, Natural Gas, Single Line:- 6.8kW ( Heat Input 8.9kW )
    • Heat Output, Natural Gas, Dual Line:- 7.27kW ( Heat Input 9.52kW )
    • Efficiency Natural Gas:- 75.9%
    • Heat Output, LPG, Single Line:- 5.2kW ( Heat Input 7.5kW )
    • Heat Output, LPG, Dual Line:- 6.5kW ( Heat Input 9.37kW
    • Efficiency LPG:- 72.1%

    Clear Front 130

    • Heat Output, Natural Gas, Single Line:- 6.81kW ( Heat Input 8.9kW )
    • Heat Output, Natural Gas, Dual Line:- 7.27kW ( Heat Input 9.52kW )
    • Efficiency:- 75.9%

    Clear Front 150

    • Heat Output, Natural Gas, Single Line:- 9.1kW ( Heat Input 10.5kW )
    • Heat Output, Natural Gas, Dual Line:- 9.73kW ( Heat Input 11.23kW )
    • Efficiency:- 85.8%

    Clear Front 150 High

    • Heat Output, Natural Gas, Single Line:- 9.1kW ( Heat Input 10.5kW )
    • Heat Output, Natural Gas, Dual Line:- 9.73kW ( Heat Input 11.23kW )
    • Efficiency:- 85.8%

    Clear Front 170

    • Heat Output, Natural Gas, Single Line:- 9.1kW ( Heat Input 10.5kW )
    • Heat Output, Natural Gas, Dual Line:- 9.73kW ( Heat Input 11.23kW )
    • Efficiency:- 85.8%

    Clear Front 200

    • Heat Output, Natural Gas, Single Line:- 10.81kW ( Heat Input 13kW )
    • Heat Output, Natural Gas, Dual Line:- 11.1kW ( Heat Input 12.7kW )
    • Efficiency:- 86.9%

    Clear Front 200 High

    • Heat Output, Natural Gas, Single Line:- 10.81kW ( Heat Input 13kW )
    • Heat Output, Natural Gas, Dual Line:- 11.1kW ( Heat Input 12.7kW )
    • Efficiency:- 86.9%